Shenzhen Selen Technology Co., Ltd

Consultation Hotline 19925361696 19925366196

Shenzhen Selen Technology Co., Ltd
CH | EN
Shenzhen Selen Technology Co., Ltd

Consultation Hotline 19925361696 19925366196

Shenzhen Selen Technology Co., Ltd

Your Position:Home > Products Center > 优利德 > Unilever UT39E+True Significant Digital Multimeter

  • Unilever UT39E+True Significant Digital Multimeter

    Model:UT39E+

    Brand:优利德

    Introduction:The UT39E is a 20000 bit true RMS, high resolution, high precision, fully functional manual shift digital multimeter. In addition to the conventional functions, the conductivity measurement function of 0.1~100nS is added, which is converted to 10MΩ~10GΩ according to the inverse ratio of the resistance. The measurement range of the resistance function of the multimeter is expanded, and the defect that it cannot measure large resistance is filled. The NCV measurement mode is optimized to improve the shortcomings of the previous measurement methods, and at the same time add sound and light prompts. The product is designed according to CAT II 1000V/CAT III 600V safety rating, with overvoltage measurement, overcurrent alarm, full gear equipped with high voltage false detection protection device. Widely used in: petroleum, chemical, aviation, ships, railways, factories, shopping malls, property and other fields of power, electrical equipment maintenance and overhaul, is a necessary test tool for electrical engineers and technicians.

  • Safety level: CAT II 1000V/CAT III 600V

    True valid value, disy a maximum of 19999 bits.

    Conductivity measurement function (0.1~100nS) converted resistance 10MΩ~10GΩ.

    交流/Dc voltage测量1000V

    20A AC/DC current measurement, with current mode switching memory function

    200MΩ resistance measurement /2000uF Capacitance measurement

    Frequency measurement 0 ~ 2MHz (sine wave/non-sine wave frequency can be measured)

    Temperature measurement (-40 ~ 1000.0℃/-40 ~ 1832℉)

    NCV:(EFHi和EFLo模式)

    Full function error detection protection, the maximum can withstand 1000V, and with overvoltage and overcurrent alarm

    The circuit is equipped with automatic power saving function, effectively extend the battery life up to 500 hours

    Diode/triode/acousto-optic alarm/backlight/low voltage disy/automatic shutdown

    Fall resistance reliability: 1 m

    Model number UT39E+
    Manual/automatic range Manual range :ACV,DCV,Ω,A
    Automatic range: temperature, frequency, capacitance
    Disy digit 19999
    Main functional technical index
    Function The range of Resolution Accuracy
    Dc voltage
    (DCV)
    200.00mV 0.01mV ±(0.05%+3)
    2.0000V 0.0001V
    20.000V 0.001V
    200.00V 0.01V
    1000.0V 0.1V ±(0.1%+5)
    Ac voltage
    (ACV)
    200.00mV 0.01mV ±(1.0%+20)
    2.0000V 0.0001V ±(0.5%+10)
    20.000V 0.001V
    200.00V 0.01V
    1000.0V 0.1V ±(1%+10)
    Ac current
    (DCA)
    2000.0uA 0.1μA ±(0.8%+10)
    20.000mA 0.001mA
    200.00mA 0.01mA
    20.000A 0.001A ±(2.5%+10)
    Direct current
    (DCA)
    2000.0uA 0.1μA ±(0.5%+5)
    20.000mA 0.001mA
    200.00mA 0.01mA ±(0.8%+5)
    20.000A 0.001A ±(2.0%+10)
    Resistance (Ω) 200.00Ω 0.01Ω ±(0.5%+10)
    2.0000kΩ 0.0001kΩ ±(0.3%+2)
    20.000kΩ 0.001kΩ
    2.0000MΩ 0.0001MΩ
    20.000MΩ 0.001MΩ ±(1.2%+20)
    200.00MΩ 0.01MΩ ±(5.0%+30)
    Conductance (nS) 0.1~100nS 0.1nS ±(1.0%+3)
    Capacitance 20.000nF 0.001nF ±(4%+20)
    200.00nF 0.01nF ±(4%+20)
    2.0000~200.00uF 0.0001~ 0.01uF ±(4%+20)
    2000.0uF 0.1uF ±10%
    Frequency (HZ) 10.000Hz~2.0000MHz 0.001Hz
    0.0001MHz
    ±(0.1%+3)
    The Celsius temperature
    (°C)
    –40℃~1000℃ 1℃ -40~40℃(±4℃)
    >40~500℃ ±(1.0%+5)
    >500~1000℃ ±(2.0%+5)
    Fahrenheit (°F) –40°F~1832°F 1℉ -40~104℉ ±5℉
    >104~932℉ ±(1.5%+5)
    >932~1832℉ ±(2.5%+5)
    Characteristic
    Triode (hFE) 0~1000β
    Diode test
    0.001V
    On-off test
    0.01Ω
    The range ofOL显示
    NCV
    Backlight
    Low voltage disy
    1 meter fall
    HOLD/Backlight HOLD/Backlight复合键
    SELECT/REL SELECT/REL复合键
    Automatic shutdown In about 15 minutes
    Safety level CATII1000V/CATIII600V
    Environmental requirements 18℃~28℃(64℉~82℉) 相对温度≤75% ;
    Ac voltage/电流频响 45~400Hz
    Automatic shutdown About 15 minutes
    Operating temperature 0℃~40℃
    一般Characteristic
    Battery 1.5Vx2 AA
    Product color Red and gray
    Product bare machine weight About 330g
    Product size 175*83*53mm
    Standard packing Color box, instruction manual, marker, temperature probe
    Standard outer box quantity 30pcs
    Standard outer box size 390×355×355mm
    Standard gross weight of outer box About 15.4kg


    Tel:19925366196
    Mobile:19925366196    
               19925361696    

    Address:1903H10, Zhuoyue Building, No. 98 Fuhua 1st Road, Futian District, Shenzhen