① Maximum disy: 4099
② True effective value measurement
Intelligent fire prevention, no need to shift
(4) Automatic identification of input signal measurement interface
⑤ With 4mF large capacitance measurement function
⑥ Large screen EBTN/NCV sound and light alarm
⑦ circuit setting automatic power saving function,
⑧ Automatic power supply power detection
⑨ Single watch pen to distinguish zero fire line, and sound and light alarm prompt
⑩ The current input hole can be automatically switched into the current measuring function
Function | The range of | Resolution | Accuracy |
Dc voltage
(DCV) |
4.000V | 0.001V | ±(0.5%+3) |
40.00V | 0.01V | ||
400.0V | 0.1V | ||
600V | 1V | ||
Ac voltage
(ACV) |
4.000V | 0.001V | ±(1.0%+5) |
40.00V | 0.01V | ±(0.8%+3) | |
400.0V | 0.1V | ||
600V | 1V | ||
Ac current
(AC mA/A) |
999.9mA | 0.1mA | ±(1.2%+3) |
9.999A | 0.001A | ||
Direct current
(DC mA/A) |
999.9mA | 0.1mA | ±(1.0%+3) |
9.999A | 0.001A | ||
Resistance
(Ω) |
400.0Ω | 0.1Ω | ±(1.0%+2) |
4.000kΩ | 0.001KΩ | ±(0.8%+2) | |
40.00kΩ | 0.01Ω | ||
400.0kΩ | 0.1KΩ | ||
4.000MΩ | 0.001MΩ | ±(1.5%+3) | |
40.00MΩ | 0.01MΩ | ±(2.0%+5) | |
Capacitance | 40.00nF | 0.01nF | ±(4%+10) |
400.0nF~400.0μF | 0.1nF~0.1uF | ±(4%+5) | |
4000uF | 1uF | ±10% | |
Maximum disy | 4099 | ||
Diode | √ | ||
On/off/buzzing | √ | ||
NCV | √ | ||
LIVE(distinguish zero fire line) | √ | ||
自动The range of | √ | ||
Low voltage disy | √ | ||
Automatic shutdown | √ | ||
Operating temperature | 0℃~40℃(32℉~104℉) | ||
Anti-fall | 1 meter | ||
The product is based on the standard | IEC61010-2010, IEC61326:2012 determination, |