Your Position:Home > Products Center > 胜利仪器 > VICTOR 1900 network base station phase determination kernel phase meter

  • VICTOR 1900 network base station phase determination kernel phase meter

    Model:VICTOR 1900

    Brand:胜利仪器

    Introduction:VICTOR 1900 wireless high voltage satellite timing remote network base station phase and nuclear phase detector system, referred to as network base station phase and nuclear phase detector, is developed and manufactured to solve the problem of simultaneously remote online testing of high and low voltage phase, nuclear phase, frequency, electricity, etc

  • The whole system and equipment of this product consists of global positioning system, base station cluster, server cluster, 2G/3G/4G communication network,315MHz/433MHz wireless communication module, handheld receiver, detector (acquisition terminal),GPS antenna,4G antenna,4G card, telescopic insulation rod, etc
    Global Positioning System (GPS) : Base stations and hand-held receivers all have built-in six-in-one multi-mode satellite timing modules to support a variety of satellite navigation systems, including China's BDS (Beidou Navigation Satellite System), GPS of the United States, GLONASS of Russia, GALILEO of the European Union, QZSS of Japan, and satellite augmenters SBAS (WAAS,EGNOS,GAGAN,MSAS), contain 32 tracking channels that can simultaneously receive GNSS signals from six satellite timing systems, and And realize joint timing and positioning, to ensure the accuracy of the test
    Base station group: Base station group consists of a plurality of base stations, the system design can be compatible 255 base stations. Base stations with all cast aluminum shell, waterproof design, installed in the secondary output end of 10kV transformer. Its built-in GPS module,4G module and 315MHz/433MHz wireless communication module serve as reference standard source. The base station transmits the collected phase, frequency and other signals to the server through the Internet. The data detected by the base station serves as the comparison standard source, and the data detected by the collector is compared with the source data of the base station
    Server farm: Multiple servers form a server farm. The server can receive data from the base station, handheld receiver, and collector respectively. The server will first analyze and compare the data of the collector and the data of the base station, obtain the phase difference and other parameters, and then send the analysis results to the hand-held receiver, hand-held receiver users can receive real-time phase information detected by any collector, can accurately identify the standard Phase A, phase B, phase C, including the basement without any communication signal ce phase core phase, and unified color code work
    Detector: nuclear phase, current different functions of the detector, detector are built GPS module,4G module,315MHz/433MHz wireless communication module, in which the current detector integrated hook design, built-in multi-layer flexible coil,315MHz/433MHz wireless communication module is easy to use handheld receiver for short distance meter reading; GPS module and 4G module communicate with the server and transmit data; Multilayer flexible coil is used to collect current and current waveform, frequency, phase and other signals
    Flexible coil: namely The Rogowski Coil, using the multilayer Roche coil technology, is an annular coil wrapped uniformly over a non-ferromagnetic material. The multilayer coil has no hysteresis effect and virtually zero phase error. The lower the phase error, the more accurate the high voltage nuclear phase is. Flexible coil no magnetic saturation phenomenon, high linearity, can meet the test current. The output signal is the differential of the current with respect to time. By integrating the output voltage signal, the input current can be truly restored. The measured current range can be from milliamps to tens of thousands of amps. The purpose of using multi-layer flexible coil is to improve the resolution of leakage current detection, can reach 10mA, and solve the test of large current, high harmonic current (up to 400 times), complex waveform current, transient impulse current and restore its waveform
    Hand-held receiver: Using 3.5 "true color LCD screen design, built-in GPS module,4G module,315MHz/433MHz wireless communication module, to receive the data sent by the server, but also to the collector, base station meter reading. The receiver disys real-time phase, frequency, current and other information on the same screen, with "X signal normal,Y signal normal,A phase,B phase,C phase, same phase, different phase" and other voice prompts, clear and intuitive, different functions of the receiver disy content is different
    Insulation rod: telescopic insulation rod, the length after stretching is about 3 meters, about 0.6 meters after shrinkage, light, with moisture-proof, high temperature resistance, impact resistance, high insulation, telescopic and other characteristics, connected to the collector, can be hung in the line test, can also be lengthening or reducing the length of the insulation rod according to the actual needs
    Nuclear phase: Common nuclear phase distance on open ground can reach 160m, satellite timing nuclear phase distance is greater than 500km, can be used for 1V ~ 550kV voltage lines all intelligent nuclear phase, can also be used for high-voltage lines and fully sealed ring network cabinet low-voltage induction point nuclear phase, in which the bare wire detector below 35kV can directly contact the nuclear phase, bare wire above 35kV using non-contact nuclear Phase, non-contact nuclear phase is to gradually close the detector to the wire under test, when the electric field signal can be induced to complete the nuclear phase, so there is no need to contact the high voltage wire directly, safe and reliable!

    Technical specifications

    System function

    Network phase, basement without any communication signal site phase, remote phase, local phase; Current, frequency, phase, phase sequence, electric test, etc. (Select detectors to test current function as required)

    Electricity source

    Base station: AC 380V (three-phase four-wire)

    Receiver: 7.4V rechargeable lithium battery, continuous operation for about 4 hours

    Detection terminal: 3.7V rechargeable lithium battery, continuous operation for about 8 hours

    Nuclear phase pattern

    基站定相Nuclear phase pattern、卫星授时模式、普通Nuclear phase pattern

    电流测试

    Hook CT with built-in flexible coil for current detection (optional detector with current function)

    Current collector

    Integrated hook type design, can test Φ168mm wire, or Φ168mm×245mm bus (optional)

    RF frequency

    315MHz,433MHz wireless transmission

    Means of communication

    Base station and server adopt 4G communication, handheld receiver and server adopt 4G communication, receiver and collector adopt 315MHz/433MHz wireless communication, to ensure network communication security and stability

    Nuclear phase distance

    远程Nuclear phase distance达500km以上

    本地Nuclear phase distance约160m

    The communication distance between the detector and the receiver is about 80m

    Disy mode

    3.5 "true color LCD disy

    Measuring range

    Nuclear phase voltage level: AC 1V ~ 550kV

    Phase: 0° ~ 360°

    Current: 0 ~ 20000A (Optional)

    Frequency: 45Hz to 75Hz

    Resolution power

    1 °. 0.01A (optional); 0.1 Hz

    Precision (23℃±5℃,80percentRH below)

    Base station phase nuclear phase, satellite timing nuclear phase: ≤±10°
    (When the base station or the measuring end of the grid load rate is relatively high phase: ≤±25°)

    Common nuclear phase: ≤±10°

    Current: ±2percent

    Frequency: ≤±2Hz

    Phase differentiation

    The real-time phase Angle difference disyed by XY receivers is in-phase or A-phase when the difference is 330° ~ 360° or 0° ~ 30°. At 90° ~ 150° is out of phase or B phase, at 210° ~ 270° is out of phase or C phase

    Voice function

    A相、B相、 C相、X信号正常、Y信号正常等Voice function

    Duration nuclear phase time

    In the satellite timing mode, after the satellite timing is successful, if there is no satellite signal, the nuclear phase can be sustained for more than 30 minutes, meeting the nuclear phase in the basement and underground mine

    Insulation rod size

    The length after stretching is about 3m; After contraction, the length is about 1m

    Nuclear phase mode

    Contact nuclear phase: 35kV and below bare wires, or 110kV and below the safe insulation skin of the conductor directly contact the nuclear phase (with insulation rod operation)

    Non-contact core phase: bare conductor above 35kV, or line above 110kV adopts non-contact core phase (with insulated rod operation)

    Base station antenna

    GPS spherical antenna, line length 5 meters; 4G antenna, line length 5 meters

    Electrical instruction

    Detector "toot toot toot" beep

    Shift gears

    Automatic shift

    Sampling rate

    2 times per second

    First search time

    It takes about 3-5 minutes for the first startup to search for satellites, about 30 seconds for the second search after the startup, and about 1 second for the subsequent hot startup. When searching for satellites, the front side of the host ne is turned upside down, and satellites are searched in empty ces around

    Satellite timing accuracy

    Is less than 30nS

    Instrument size

    Base station: length width 300mm×200mm×85mm

    Nuclear phase detector: Length width width 145mm×60mm×48mm (single function)

    Current detector: Length width thickness 310mm×270mm×52mm (optional)

    Receiver: Length and width 250mm×100mm×40mm

    Backlight control

    Press the up and down arrow keys to adjust the backlight brightness

    Induction intensity control

    According to the intensity of the induced electric field is different, the detector can automatically control the amplification, which is convenient for the nuclear phase in dense ces

    Data retention

    Press the HOLD key to HOLD data in test mode, then press the Hold key to cancel hold

    Exit function

    Press ESC to exit the current function screen and return to the upper-level directory

    Data retrieval

    按ENTER进入Data retrieval模式后,按箭头键翻阅存数据

    Star search directions

    The "----" symbol is disyed dynamically when searching for satellites

    Automatic shutdown

    开机约30分钟后,仪表Automatic shutdown,以降低电池消耗

    Rated current

    Detector: 35mA max; Receiver: 300mA max; Base station: 10mA max

    电池电压

    When the battery power is low: the detector power indicator blinks slowly to remind charging; Receiver battery low voltage symbol disy, remind to charge

    Instrument quality

    Base station: 1.6kg(including accessories)

    Detector: 205g(including battery)

    Receiver: 395g(including battery)

    Insulation rod: 1.45kg

    Total mass: 12.6kg(including instrument box)

    Working temperature and humidity

    -10℃ ~ 40℃; 80percentRh below

    Storage temperature and humidity

    -10℃ ~ 60℃; 70percentRh below

    Interference

    No extra-strong electromagnetic field; No 433MHz,315MHz simultaneous interference

    Insulation strength

    Insulation rod: AC 110kV/rms(5 sections of insulation rod after stretching, between the ends)

    Detector: 2000V/rms(before the front and rear ends of the housing)

    Receiver: 2000V/rms(before the front and rear ends of the housing)

    Structure

    Drip-proof type II,IP63

    Suitable for safety rules

    GB13398-92, GB31.1-311.6-8,3DL408-91 standard and the national newly issued power industry standard "1kV ~ 35kV portable nuclear phaser general technical conditions DL/T971-2005" requirements