Technical specifications:
Transmitter specifications |
|
|
Model number |
VICTOR 7500 |
VICTOR 7500A |
Work energy |
Generate pulse code current signal; Disy the remaining battery voltage |
Emit compound pulse frequency current signal, disy remaining battery voltage, dynamic indication of emission state |
Electricity source |
11.1V large capacity rechargeable lithium battery, fully charged continuous operation for about 8 hours |
|
Disy mode |
大LCD实时显示剩余Battery voltage |
|
Pulse voltage |
500V(power failure identification) |
|
Pulse current |
Max. 30A (depending on the resistance of the loop) |
Max 5A (depending on the size of the loop resistance) |
Pulse frequency |
1 time/second |
|
Pulse width |
2ms |
|
Test line length |
5 meters with alligator clip, 1 each red and black |
3 meters with alligator clip, 1 each red and black |
Backlight control |
Yes, white backlight |
|
Pressure resistance |
Transmitter adopts integrated special tool box design, box can withstand about 200kg of pressure |
|
Pressure resistance |
AC 3700V/rms(before top and bottom of instrument case) |
|
Electromagnetic properties |
IEC61326(EMC) |
|
Refer to safety rules |
IEC61010-1(CAT Ⅲ 300V,CAT IV 150V, pollution level 2) |
|
|
|
|
接收机规格 |
|
|
Basic functional features |
VICTOR 7500 |
VICTOR 7500A |
Work energy |
电缆识别(识别并解码Pulse current信号);交流电压测量 |
Live cable identification, power failure cable identification; Ac voltage, current, frequency measurement |
Electricity source |
7.4V large capacity rechargeable lithium battery,USB charging interface, fully charged continuous operation for about 6 hours |
|
Rated current |
About 180mA max |
About 300mA max |
Disy mode |
3.5 "true color LCD disy, color electronic dial indicator |
3.5 "true color LCD disy, color icon indication |
Cable identification is successful |
Green grating clockwise dynamic indicator |
The green checkmark indicates (√) |
Non-target cable |
Red and orange grating counterclockwise dynamic indication |
Red - orange cross icon indicates (×) |
Receiver size |
Length width and thickness 207mm×101mm×45mm |
|
Flexible coil |
Length about 630mm, line diameter 6 mm or 12.5mm |
|
Inside diameter of coil |
φ200mm |
|
Lead length |
Flexible coilLead length:2m |
|
Voltage test line |
1m long (1 red and 1 black) |
|
Detection range |
Power failure recognition: the coil can detect the pulse signal of the loop resistance of 0Ω ~ 2kΩ; When the resistance of the detection loop is 2kΩ, ensure that the battery power of the transmitter is more than 10V |
Power failure recognition: the coil can detect the pulse signal of the circuit resistance of 0Ω ~ 10kΩ; When the resistance of the detection loop is 10 Kω, ensure that the battery power of the transmitter is more than 11V |
|
Electric identification: the coil can detect the pulse signal of the circuit resistance of 0Ω ~ 200Ω; When the detection loop resistance is 200Ω, ensure that the battery power of the transmitter is more than 11V (the cable length is generally 0 to 5 km, which depends on the ground resistance and cable resistance) |
|
The range of |
AC voltage: AC 0.01V to 600V(50Hz/60Hz) |
Ac voltage: 0.00V to 600V(50Hz/60Hz) |
|
Ac current: 0.00A to 5000A(50Hz/60Hz) |
|
|
Current frequency: 45Hz to 70Hz |
|
Precision |
Ac voltage: ±1percent±1dgt |
Ac voltage: ±2percent±3dgt |
|
Ac current: ±2percent±3dgt |
|
|
Current frequency: ±2percent±3dgt |
|
Outage identification impedance |
2000 euros |
8000 euros |
Identification signal |
Color raster dynamic disy signal strength |
Color signal amplitude and digital disy |
Detection rate |
约1 time/second |
|
Backlight control |
Press the up and down arrow keys to adjust the LCD backlight brightness |
|
Automatic shutdown |
开机约15分钟后,仪表Automatic shutdown,以降低电池消耗 |
开机约30分钟后,仪表Automatic shutdown,以降低电池消耗 |
Battery voltage |
当Battery voltage低于6.5V时,Battery voltage低符号显示,提醒给电池充电 |
当Battery voltage低于6.5V时,Battery voltage低图标显示,提醒给电池充电 |
Receiver quality |
Current clamp: 172g; Receiver: 370g(with battery) |
Current clamp 172g; Receiver 370g(with battery) |
The absolute fate of |
≥100MΩ-- between instrument line and sheath housing |
AC2000V/rms(Before the front and rear ends of the housing) |
Suitable for safety rules |
IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326, pollution level 2 |
IEC61010-1 CAT Ⅲ 600V,IEC61010-031,IEC61326, pollution level 2 |
Note: VICTOR 7500 is limited to the target cable of power failure, that is, no live identification; The VICTOR 7500A can recognize electrical charges |