  • JK9200 multi-channel temperature and power recorder

    Model:JK9200

    Brand:金科JINKO

    Introduction:This product is a single-phase three-phase comprehensive measurement and acquisition instrument for AC single-phase circuit full parameter measurement Adopt high precision 24-bit AD chip, dynamic range ratio up to 1000:1 True RMS measurement, the measurement parameters include voltage, current, frequency, active power, reactive power, power factor, harmonic power, cumulative power and other electrical parameters, high accuracy, good stability, high communication rate. Full isolation processing technology, strong anti-interference ability. The measured power parameters are output by RS-485 digital interface to achieve remote transmission. The MODBUS protocol of the product is fully compatible with the MODBUS(RTU) protocol in various configuration software or PLC equipment.

  • Product Description:

    This product is a single-phase three-phase comprehensive measurement and acquisition instrument for AC single-phase circuit full parameter measurement; Adopt high precision 24-bit AD chip, dynamic range ratio up to 1000:1;

    True effective value measurement, measurement parameters such as voltage, current, frequency, active power, reactive power, power factor, harmonic power and accumulated power and other electrical parameters, high accuracy, good stability, high communication rate

    Full isolation processing technology, strong anti-interference ability. The measurement of electricity parameters through RS-485 digital interface output to achieve remote transmission, the product MODBUS protocol is fully compatible with a variety of configuration software or PLC equipment in

    MODBUS(RTU)协议.

    Product Features :

    * sampling period has 20 ms, 40 ms, ms, 60 80 ms and 100 ms and 400 ms and 1000 ms seven rate can be set up....
    * With odd check, even check, no check, stop bit and other communication formats can be set freely.
    * Communication rate and address with software or hardware setting two modes, easy to use
    * Power has positive and negative cumulative storage function respectively, with power failure saving function
    * With a variety of operating indicators, the red light indicates the normal operation of the product (100mS blinking), the green light indicates the product communication
    * Strong anti-interference ability, input, output, power port surge resistance voltage up to 2KV
    *MODBUS protocol product data output negative numbers are output by complement;


    Technical parameters:

    Model number

    JK9200

    JK9200B

    Connection mode

    Single-phase two-wire/three-phase four-wire/three-phase three-wire

    Single-phase two-wire

    Show

    High brightness color 10.1 "TFT LCD

    Number of power meter channels

    1

    4 (Adding channels requires customization)

    Number of temperature channels

    8 (Adding channels requires customization)

    8 (Adding channels requires customization)

    Temperature measurement range

    Thermocouple: J/K/T/E/S/N/B PT100

    Temperature measurement accuracy

    ≦±0.2%F.S

    Measuring items

    Voltage V, current A, active power W, power factor,
    Reactive power VAR, frequency Hz, apparent power VA,
    Positive and reverse electrical measurement Kw.h,, fundamental power W,
    Harmonic power W, total harmonic power W, temperature simultaneously

    Measurement and acquisition.

    Voltage V, current A, active power W Temperature ℃

    Form of measurement

    True effective value Trms

    Curve (History, real time)

    Temperature, voltage, current, power

    Voltage range

    10V,100V,250V,400V,500VAC

    Current range

    10mA, 100mA,1A,5A,10A,20A(larger than 5A with perforated type, perforated aperture 7.5mm)

    Power range

    0.01W-12kW

    Power factor range

    0.001-1.000 Calculation method:
    Watt (W) ÷[voltage (V) × current (A)]= power factor (PF)

    Frequency range

    40-400Hz

    Frequency response

    30Hz-1KHz

    Basic accuracy

    0.5%FS

    Measure the speed of

    3 times per second

    Voltage input impedance

    2 k Ω / V; (For example, if the input is 250V, the voltage impedance is 500 Kω)

    Operating temperature

    -20℃~+60℃

    Output interface

    RS485(Standard Modbus-RTU communication protocol)

    Volume

    Instrument size: 220*275*180mm (H*W*D)

    Attachment

    Power cord, warranty card, instruction manual, thermocouple, inspection certificate