Features:
Most suitable for controlling the temperature of the object.
In order to facilitate pipe distribution and operation, the vacuum pump connection valve and vacuum gauge are located at the front operating panel
Double doors made of tempered glass doors and polycarbonate for their protective effect.
Heat-resistant silicone pad, strong durability, good air tightness.
In addition to easy to confirm the measured value and set value of PV,SV two-stage disy, but also use to prevent excessive temperature disy
Standard timer (4 kinds), program operation (16 steps 8 modes). Temperature record (Bluetooth® communication) plus output AC100V1A when an error occurs
The internal sensor can directly detect and adjust the sample temperature to eliminate the difference between the sample temperature and the set temperature
【 Wireless Recorder App features 】
The measured temperature and set temperature can be confirmed even at a distance.
Record the measured temperature and set temperature in the substrate memory at certain intervals.
Intuitive operation even without manual.
Read data will be automatically converted into CSV format attachments, just enter the email address can be sent to the computer and other attachments, attachments can be opened by EXCEL and other table calculation software, you can chart the data, or edit it, make a form
Read data, even if the power is off the data will be stored in the substrate until the data is deleted.
Start/stop recording from APP, delete record.
The record will automatically stop when the memory is full.
Specifications:
Additional functions: timer function, program function, week, time specified timer
Sensor :K thermocouple (for direct temperature control of the specimen, to prevent excessive rise with each 1)
Safety device: prevent excessive rise function (digital set), self-diagnosis function (heater break detection, sensor abnormal detection), overcurrent circuit breaker
Recording period :2 seconds /10 seconds /30 seconds /1 minute /10 minutes /60 minutes
Disy period :2 seconds /10 seconds /30 seconds /60 seconds /300 seconds
Recording mode: full stop (full storage stop recording)
Record format :CSV format
▼ Corresponds to OS:iOS11.4 and later
▼对应机种:iPhone5s・5c・6・6Plus・6s・6s・6sPlus・SE・7・7Plus・8・8Plus・X
Additional functions: timer (ON timer, OFF timer, SV start, ON/OFF timer)/ Maximum 16 steps ×8 modes of temperature gradient program/week/time specified timer
Error output :AC100V1A output (M4 terminal station)
Material
▼ Exterior: baking paint coating
▼ Interior :SUS304
▼ Shelf: Aluminum
▼阀(c-3771, c-3604)——
▼ Vacuum meter: Brass (C2680TW,C3604BD)
Door seal: silicone rubber
Observation window: reinforced glass (10mm thick), polycarbonate protective te
Heating mode: tank heating mode
Temperature setting range :60°C
Vacuum range :10kPa
Control mode :PID control,SSR output
Valve diameter: outer diameter φ30mm
【 Specification sheet 】
※ It takes about 18 days to ship from Japan in case of storage in Japan