Product Overview: Fluke 101/101Kit digital multimeter
Fluke 101/101Kit digital multimeter is used for basic electrical testing, and can be used by civil/commercial electrical electricians and heating and air conditioning technicians for reliable testing. This digital multimeter is compact, lightweight and comfortable to hold. It is also strong and durable and can be used daily for many years. If you need an affordable professional grade multimeter,Fluke 101/101Kit digital multimeter is your better choice
Product specifications: Fluke 101/101Kit digital multimeter
Electrical technical specifications | ||
Ac voltage (40-500Hz) | The range of | 600.0 mV
6.000 V 60.00 V 600.0 V |
Resolution | 0.1 mV
0.001 V 0.01 V 0.1 V |
|
Precision | 3.0percent±3 digits
1.0percent±3 digits |
|
Dc voltage | The range of | 6.000 V
60.00 V 600.0 V |
Resolution | 0.001 V
0.01 V 0.1 V |
|
Precision | 0.5percent± 3 digits | |
电阻(欧姆) | The range of | 400.0 Ω
4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
Resolution | 0.1 Ω
0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
|
Precision | 0.5%±3‰——
0.5%±2‰ 0.5%±2‰ 0.5%±2‰ 0.5%±2‰ 1.5percent±3 |
|
Capacitance | The range of | 50.00 nF
500.0 nF 5.000 μF 50.00 μF 500.00 μF 1000.0 μF |
Resolution | 0.01 nF
0.1 nF 0.001 μF 0.01 μF 0.1 μF |
|
Duty cycle | The range of | 0.1% ~ 99.9%—— |
Resolution | 0.10% | |
General technical index | ||
CAT level | CAT III 600 V | |
交流电压The range of | 600.0 V | |
Dc voltageThe range of | 600.0 V | |
电阻The range of | 40.00 MΩ | |
Automatic shutdown | Y | |
Continuity | Y | |
Capacitance器 | 100.0 μF | |
Frequency | 100.0 kHz | |
Keep | No | |
Duty cycle | It is | |
The size | 130 mm x 65 mm x 27mm | |
The weight of | 160 g | |
Battery | 两节 AAA Battery | |
Warranty period | 1 year | |
Environmental specifications | ||
Operating temperature | 0°c - 40°c | |
Storage temperature | -30°c - 60°c | |
Operating humidity | No condensation (< 10 °C)
< =10 Relative humidity 90percent (10 °C to 30 °C) < =10 Relative humidity 75percent (30 °C to 40 °C) (No condensation) |
|
Operating humidity,40 MΩ | The relative humidity is 80percent (10 °C to 30 °C) and 70percent (30 °C to 40 °C) | |
Working altitude | 2000 m | |
Storage elevation | 12000 m | |
Protection level | 根据 IEC 60529,Protection level为 IP 40 | |
Vibration requirement | MIL-PRF-28800F Class 2 | |
Drop test requirements | -10°C and 1 m above ground in accordance with IEC-61010-1 and Fluke SOP 39.1-- for portable handheld devices
Container drop test is based on Fluke SOP 39. |
|
EMI, RFI, EMC | Must conform to all
Requirements for IEC/EN 61326-1 |
|
Absorption/corrosion | According to the requirements of Fluke SOP 39.1 | |
Temperature coefficient | 在 28 °C 以上或 18 ºC 以下,每摄氏度增加 0.1 x Precision |