Product specifications: Fluke 179C true RMS digital multimeter
Technical index | ||
Dc voltage | Precision ¹ | ±(0.09% + 2) |
Maximum resolution to ground | 0.1 mV | |
The maximum value | 1000 V | |
Ac voltage | Precision ¹ | ±(1.0% + 3) |
Maximum resolution to ground | 0.1 mV | |
The maximum value | 1000 V | |
Direct current | Precision ¹ | ±(1.0% + 3) |
Maximum resolution to ground | 0.01 mA | |
The maximum value | 10 A | |
Ac current | Precision ¹ | ±(1.5% + 3) |
Maximum resolution to ground | 0.01 mA | |
The maximum value | 10 A | |
Resistance | Precision ¹ | ±(0.9% + 1) |
Maximum resolution to ground | 0.1 Ω | |
The maximum value | 50 MΩ | |
Capacitance | Precision ¹ | ±(1.2% + 2) |
Maximum resolution to ground | 1 nF | |
The maximum value | 10,000 µF | |
Frequency | Precision ¹ | ±(0.1% + 1) |
The maximum value分辨率 | 0.01 Hz | |
The maximum value | 100 kHz | |
Temperature | Precision ¹ | ±(1.0% + 10) |
Maximum resolution to ground | 0.1 °C | |
The range of | -40 °C / 400 °C | |
1. Accuracy refers to the best accuracy of each function | ||
Environmental indicators | ||
工作Temperature | -10°c - 50°c | |
存放Temperature | -30°c - 60°c | |
Humidity (no condensation) | 0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 50 °C) |
|
Safety specifications | ||
Class of overvoltage | En 61010-1
En 61010-1: 600v cat iv—— |
|
Agency approval | UL,CSA, TUV are listed,VDE to be determined | |
Mechanical and general specifications | ||
Size | 43 x 90 x 185 mm | |
The weight of | 420 g | |
Warranty period | For life | |
Battery life | Alkaline battery usually ~200 hours, no backlight |