Products overview: the Fluke 360 leakage current clamp meter | leakage current tester
Fluke 360 leakage current tester is durable and high accuracy, is an excellent leakage current measuring instrument
As a well-designed non-invasive insulation condition testing tool,Fluke 360 leakage current tester allows you to test without shutting down system power or disconnecting equipment -- saving time and without adversely affecting resistance quality or safety
Fluke 360 leakage current tester adopts unique clamp design, eliminating the interference of adjacent current wire, and reducing the influence of external magnetic field, even in a very small current environment, also can ensure the accuracy of the test data. In this way, you can perform accurate, reliable testing in today's complex electrical environment. Fluke 360 leakage current tester has (strong high-quality jaws,) a high degree of stability and excellent durability, strong and high-quality clamp design to ensure a high degree of stability and long-term repeatability
Product specifications: the Fluke 360 leakage current clamp meter | leakage current tester
常规技术指标 | |
---|---|
检测方法 | The average value |
Show | 数字Show:3200 计数柱图Show:32 段,LCD |
Measurement period | 每秒 2 次(数字Show),每秒 12 次(柱图Show) |
Range switching | Automatically adjust the range |
Ambient temperature and humidity | 0 ° C-50 °C,80 percent RH or less (non-condensing) |
Temperature coefficient | 0.05percent of range / °C (0 ° C-18 °C and 28 ° C-50 °C, measuring range 0-50 A) |
The influence of external magnetic fields | 0.0005 percent is typical of |
The effect of conductor position | Within the range of accuracy |
Circuit voltage | <300 Vrms |
Safety standards | EN 61010-1,EN 61010-2-032,300 V CAT III, Level 2 pollution protection |
Withstand voltage | 3.7 kV ac |
Battery type | 1 x 3 V Lithium battery (button battery) CR2032 |
Battery life | About 90 hours (continuous use) |
Automatic shutdown | About 10 minutes |
The diameter of the conductor can be measured | Max. 40 mm |
The weight of | 200 g |
Size | 176 mm x 70 mm x 25 mm |
Operating altitude | 2000 m |
Electrical technical specifications | |
Standard operating environment | 23 ± 5 ºC, the maximum relative humidity 80 percent |
Accuracy | (percent Indicates the value of the least significant digit in the reading) |
3 mA | Accuracy: 1percent 5 Max. Allowable current: 60 A rms |
30 mA | Resolution: 0.01 mA Accuracy: 1percent 5 Maximum allowable current: 60 A rms |
30 A | Resolution: 0.01A Accuracy: 1percent 5 Maximum allowable current: 60 A rms |
60 A | Resolution: 0.1A Accuracy: 5percent 5 Maximum allowable current: 60 A rms |
The average value检测和真有效值校准 | Standard frequency for accuracy: 50/60 Hz |