testo 316-3 refrigerant leak detector (refrigerant leak detector), can detect CFC,HCFC,HFC refrigerant. Includes sensors, instrument cases, exit reports, batteries, spare filters, and operating manuals
Product Introduction:
testo 316-3 refrigerant leak detector, can detect CFCS, HCFCS,HFC refrigerant, including sensor, instrument case, factory report, battery, spare filter and operating manual.
High sensitivity
The minimum leak detection sensitivity is 4 g/a(g/ year) in compliance with SAE J1627/ EN 14624 and F-GAS(fluorinated gas) regulations.testo 316-3 is a good way to help customers' refrigeration systems comply with the relevant regulatory requirements
Automatic zero, simple operation
testo 316-3 zero adjustment function, effectively eliminate the interference of environmental background factors, even in the environment with gas or other refrigerant pollution, can also be accurate leak detection. At the same time, the instrument only needs to be operated with one key, without pre-setting, and can be started to test after the machine is turned on
LED sound and light alarm
The five-stage LED indicator quickly and in real time indicates the leak point and the amount of leakage. Can also be audible alarm, convenient customer can not observe the LED disy in the occasion
The sensor can be reced by itself
testo 316-3 uses "heating diode" to ensure 80-100 hours of service life. Customers can change their own sensors, to ensure that the sensitivity of refrigerant leak detector to maintain the best state
Advantages at a glance:
Leak detection sensitivity 4 g/a(g/ year)
Suitable for leak detection of all common refrigerants
One-key operation, no preset, boot can start detection
LED indicator light, quickly and clearly find the leak point and leak point size
Automatic zero function, effectively eliminate the interference of environmental background factors
Compliance with SAE J1627/ EN 14624
Users can rece the sensor by themselves
Technical parameters | |
---|---|
Sensitivity |
4g/a (g/ year) |
Detectable refrigerant | R22,R134a,R-404A,R-410A,R507,R438 and all CFCS, HFCS, and HCFCS |
Comply with the regulations | SAE J1627、EN14624、EG 2004/108/EG |
Call the police | LED和声音Call the police |
Operating temperature | - 20 ~ 50°C |
Operating humidity | 20 ~ 80%RH |
Storage temperature | 0 ~ 50°C |
Storage temperature | 0 ~ 50°C |
Power supply | 2 D Type 1 batteries |
Battery life | Use it continuously for 16 hours |
Sensor life | 80 ~ 100 hours |
The weight of | About 500g(including battery) |