testo 340烟气分析仪 ,包括充电电池,出厂报告及背带 ,Standard configuration O2 Sensor and differential pressure /流速Sensor.
Product Introduction:
The increasing fuel cost makes it more and more important to use flue gas analysis to improve the combustion efficiency of boilers. A practical, simple and portable flue gas analyzer is the most ideal choice
testo 340
Only with the standard
O2
Sensor
,
The rest
3
个Sensor可根据不同应用而任意选择搭配.紧凑的设计,值得信赖的技术使得
testo 340
It can be used in the following applications:
•
Environmental monitoring;
•
Energy saving monitoring;
•
Testing of stationary engines;
•
Turbine detection
预即插即用的备用Sensor
3
个自由选择的Sensor插槽
(
Standard configuration
O2
,
At least
2
个Sensor方可工作
) CO, COlow
, NO, NOlow
, NO2
And
SO2
testo 340
Standard configuration差压
/
Flow rate measurement function
的The range of扩展功能, standard with单个SensorThe range of扩展或Optional有SensorThe range of扩展
Automatic flow control air pump
Modular smoke probe
Data storage function
Optional
:
Data is transmitted through
USB
And
easyEmission
Computer software connection
10
A kind of built-in fuel,
10
A user-defined fuel
–
The fuel coefficient can be passed by
easyEmission
Software to calculate
testo 340
At least
2
个Sensor方可进行工作,多可配备
4
个Sensor
.
testo 340 Technical parameters |
|
---|---|
|
Describe |
Fuel |
10A kind of built-in fuel,10A user-defined fuel, And测试气体 |
Storage temperature |
-20 - +50 ℃ |
Operating temperature | -5 - +50 ℃ |
The weight of |
960 g |
Size |
283×103×65 mm |
Power supply |
Rechargeable battery 3.7V / 2.4Ah
|
Show |
曲线Show,160×240 像素 |
Shell material | TPE PC |
Protection level | IP40 |
Warranty |
1 year |
Memory |
|
---|---|
At most accommodate |
100 folders |
Each folder |
At most accommodate10个测量点 |
Each measuring point |
At most accommodate200组数据 |
That is, the maximum storage | 200,000 sets of data |
Automatic flow control pump |
|
---|---|
Pump flow rate |
0.6l /min (constant control) |
Hose length |
Max. 7.8m (by connecting extension hose) |
Maximum positive pressure/flue gas resistance |
+50 hPa |
Maximum resistance to negative pressure/smoke | -200 hPa |
Temperature measurement Type K thermocouple (NiCr-Ni) |
|
---|---|
The range of |
-40 - +1200 ℃ |
Precision |
± 0.5 °C (0 - +100 ℃)
|
Resolution |
0.1 ℃ |
Suction force measurement |
|
---|---|
The range of |
-40 ~ +40 hPa |
Precision |
±0.03 hPa (-2.99 ~ +2.99 hPa)
|
Resolution |
0.01 hPa |
Differential pressure measurement |
|
---|---|
The range of |
-200 ~ 200 hPa |
Precision |
±0.5 hPa(-49.9 ~ 49.9 hPa)
|
Resolution |
0.1 hPa |
Absolute pressure measurement |
|
---|---|
The range of |
600 ~ +1,150hPa |
Precision |
±10 hPa |
Resolution |
1 hPa |
O2测量
|
|
---|---|
The range of | 0 ~ +25 Vol.% O2 |
Precision | ±0.2 Vol.% |
Resolution | 0.01 Vol.% |
CO测量(H2补偿) |
|
---|---|
The range of | 0 ~ 10,000 ppm |
Precision | ± 10 ppm (0 - 199 ppm)
|
Resolution | 1 ppm |
COlow测量(H2补偿)
|
|
---|---|
The range of | 0 ~ +500 ppm CO |
Precision | ±2 ppm (0 ~ 39.9 ppm)
* Data from 20°C environment |
Resolution | 0.1 ppm CO |
NO measurement
|
|
---|---|
The range of | 0 ~ +3000 ppm NO |
Precision | ± 5 ppm (0 - 99 ppm)
|
Resolution | 1ppm NO |
NO低测量 |
|
---|---|
The range of | 0 ~ +300 ppm |
Precision | ± 2 ppm (0 - 39.9 ppm)
|
Resolution | 0.1 ppm |
NO2测量 |
|
---|---|
The range of | 0 - 500 ppm |
Precision | ±10 ppm (0 ~ 199 ppm)
|
Resolution | 0.1 ppm |
SO2测量 |
|
---|---|
The range of | 0 - 5000 ppm |
Precision | ±5 ppm (0 ~ +100 ppm)
|
计算参数 | The range of | Resolution |
---|---|---|
燃烧效率 | 0 ~120 % | 0.1% |
Smoke loss | 0 ~99.9 % |
0.1% |
Dew point of smoke | 0 ~ 99.9 °C |
0.1 °C |
CO2,由O2计算 |
|
---|---|
Show范围 | 0 - CO2max |
Precision | ± 0.2 Vol.% |
Resolution | 0.1 vol.% |