testo 521-1 Differential Pressure Meter, 0... 100 hPa / -0.2 percent fsv, including battery and factory report.
Product Introduction:
testo 521-1 High precision pressure gauge with built-in pressure sensor 0 to 100 hPa Suitable for measuring flow rates 0 to 100 m/s with pitot tube.testo 521-1 has 2 accuracy grades.testo 521-1 has a built-in pressure sensor rated 0.2percent. The external 100 Pa probe can measure the wind speed range of 1 ~ 12 m/s. Measurement data are stored directly in the instrument and analyzed by computer, or printed on site by testo printer
Advantages at a glance:
Differential pressure probe has temperature compensation
2 probe jacks for connecting pressure and temperature probes
Direct calculation of wind speed and volume
Multi-point mean and time mean calculation
Air density compensation
Two 4 to 20 mA output jacks are used to connect instruments for signal output of host measurement parameters
The testo 521 can also supply power to transmitters, such as 4 to 20 mA sockets that can be connected to testo 521,526,400,650, and 950 handheld instruments
2 custom probes allow connection of external probes for pressure, temperature, current/voltage, etc
Technical parameters |
|
---|---|
Storage capacity |
25000 |
The disy screen |
LCD The disy screen 7 字节显示 |
Storage temperature |
-20 ~ +70 °C |
Operating temperature |
0 ~ +50 °C |
Power supply |
Battery, storage battery, power supply 12V |
Battery type |
9 V (6LR61) |
The weight of |
300 g |
Size |
219 x 68 x 50 mm |
Material/shell |
ABS |
Probe type NTC |
|
---|---|
The range of |
-40 ~ +150 °C |
Precision |
±0.2 °C (-10 ~ +50 °C)
±0.4 °C (剩余The range of) |
Resolution |
0.1 °C |
Probe type K thermocouple |
|
---|---|
The range of |
-200 ~ +1370 °C |
Precision |
±0.4 °C (-100 ~ +200 °C)
±1 °C (剩余The range of) |
Resolution |
0.1 °C |
Probe type Voltage probe |
|
---|---|
The range of |
0 ... 10 V |
Precision |
±0.01 V |
Resolution |
0.01 V |
Probe type piezoresistive pressure sensor |
|
---|---|
The range of |
0 ... 100 hPa |
Precision |
±0.2 percent of the measured value |
Resolution |
0.01 hPa |
Overload |
300 hPa |
Probe type Pressure probe |
|
---|---|
The range of |
-1 ~ 400 bar |
Precision |
±0.2 percent of the measured value |
Resolution |
0.01 bar |