  • Fluke 719Pro Electric Pressure Calibrator

    Model:Fluke 719Pro

    Brand:FLUKE

    Introduction:Key features Unique integrated electric pump suitable for one-hand calibration of pressure Easy to use switch test function allows easy test of pressure switch Precision pressure trimmer knob allows accurate and simple calibration of pressure

  • Product specifications: Fluke 719Pro electric pressure calibrator

    Measure
    Fluke-719Pro-30G The range of -12 - 30psi / -0.8 - 2bar
    Resolution 0.001 psi / 0.0001 bar
    Fluke-719Pro-150G The range of -12 - 150psi / -0.8 - 10bar
    Resolution 0.01 psi / 0.001 bar
    Fluke-719Pro-300G The range of -12 - 300psi / -0.8 - 20bar
    Resolution 0.01 psi / 0.001 bar
    Accuracy 满The range of的 ±0.025%,6 个月
    满The range of的 0.035%,1 年
    温度影响(有The range of) Add ±0.002percent F.S./°C-- when the temperature is outside the range of 15 °C to 35 °C
    Dry air and non - corrosive gases only
    No effect on accuracy of all functions in the range of 15 °C to 35 °C
    Function The range of Resolution Accuracy(1 年)
    直流 mA(模拟和Measure) Dc 0-24 mA 0.001 mA ±0.015percent of the reading ± 2 counts
    The maximum load in mA output is 1000 Ω, and the maximum voltage in mA simulation is DC 26 V
    直流电压(仅限Measure) Dc 30 V 0.001 V ±0.015percent of the reading ± 2 counts
    不能Measure交流电压,直流电压不能过 30 V
    温度(仅限Measure,Pt100 RTD) -50 - 150 °C
    (-50°f - 302°f
    0.01 °C
    0.01 °F
    ±0.1°c(0.2°f)——
    The 720 RTD probe (optional attachment) has ± 0.25 °C (± 0.45 °F) synthetic uncertainty
    Loop power supply Dc 24 V N/A 24 mA/24 V
    温度影响(有Function) - - Add ±0.002percent F.S./°C-- when the temperature is outside the range of 15 °C to 35 °C
    No effect on accuracy of all functions in the range of 15 °C to 35 °C
    Use the environment
    Operating temperature -10°c - 50°c
    Storage temperature (with batteries) Follow the battery manufacturer's technical specifications (see below for storage technical specifications)
    Storage temperature (no battery) -20°c - 60°c
    Power requirements
    Battery 8 节 标准 5 号碱性Battery
    Battery寿命 At least 300 pump cycles at 150 psi; At least 1000 pumps at 30 psi; At least 100 pumps circulating at 300 psi
    Fuselage specifications
    Dimensions (height x width x depth) 24.13 x 11.18 x 7 cm (9.5 x 4.4 x 2.8 in)
    The weight of With Holster 1.2kg (2.5lb)
    Connect
    Pressure NPT connection with 1/8 inch internal thread
    Electrical Standard banana socket
    RTD 4 pin miniature round
    External module 6 pin miniature round
    Engineering Unit (configurable)
    psi、bar、mbar、kPa、kgcm²、cmH2 O @ 4 °C、cmH2 O @ 20 °C、mH2 O @ 4 °C、mH2 O @ 20 °C、inH2 O @ 4 °C、inH2 O @ 20 °C、inH2 O @ 60 °F、mmHg @ 0 °C、inHg @ 0 °C、ftH2 O @ 4 °C、ftH2 O @ 20 °C、ftH2 O @ 60 °F